For further information on ganging Nova®, visit www.lutron.com/customganging.
1
PowerPack required for line voltage switching.
2
VETS-R-Auxiliary electronic tapswitches do not require derating.
No fins broken 1 fin broken 2 fins broken
Incandescent
Dimmers
600 W 500 W 300 W
1000 W 900 W 700 W
1500 W 1250 W 1000 W
1950 W
Magnetic low-voltage
Dimmers
600 VA / 450 W 500 VA / 400 W 300 VA / 250 W
1000 VA / 800 W 900 VA / 750 W 700 VA / 500 W
1500 VA / 1200 W 1250 VA / 1000 W 1000 VA / 800 W
Electronic low-voltage
Dimmers
300 W 300 W 250 W
600 W 500 W 400 W
Fluorescent
Hi-lume
®/Hi-lume® Compact SE/Eco-10®/EcoSystem®
Vareo 20 ballasts / 8 A 20 ballasts / 6 A 20 ballasts / 4.5 A
Nova Tb
6 A no derating no derating
8 A no derating no derating
16 A no derating no derating
0-10 VDC control
1
30 mA ballasts no derating no derating
Tu-Wire
® 5 A 4 A 3.3 A
Fan controls
Quiet 3-speed 1.5 A no derating no derating
Fully variable 6 A 4.2 A 2.5 A
Fully variable 12 A 10 A 8.3 A
Electronic tapswitches
2
VETS-1000- 1000 W 800 W 650 W
VETS-1000-SL- 1000 W 900 W 700 W
VETN-1000- 1000 VA 700 VA 550 VA
Derating Table 2
Architectural | Vareo
®, Nova Tb®
173
www.lutron.com | 1.800.523.9466 |
Appendix | Multi-ganging and deratingAppendix | Multi-ganging and derating