Installation
26
Adjusting the minimum setting for natural
or city gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: The
flame should not go out. Repeat the
operation on all gas taps.
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
tap rod clockwise all the way.
Lubricating the gas taps
Over time the gas taps may become difficult
to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Burner and nozzle characteristics tables
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
Lubrication of the gas taps should
be performed by a specialised
technician.
Natural Gas – G20 20 mbar SR R UR
Rated heating capacity (kW)
1.8 3.0 6.5
Nozzle diameter (1/100 mm)
95 125 185
Reduced capacity (W)
500 1200 2300
Primary air (mm)
1.5 1.5 2.5
LPG – G30/G31 29 mbar SR R UR
Rated heating capacity (kW)
1.8 3.0 6.2
Nozzle diameter (1/100 mm)
62 85 115
Reduced capacity (W)
500 1200 2300
Primary air (mm)
1.5 2 -
Rated capacity G30 (g/h)
131 218 451
Rated capacity G31 (g/h)
129 214 443
City Gas – G110 10 mbar SR R UR
Rated heating capacity (kW)
1.8 3.0 5.3
Nozzle diameter (1/100 mm)
165 230 420
Reduced capacity (W)
500 1200 2300
Primary air (mm)
0.5 1.5 4