INSTALLATION
ENGLISH
Connecting Electricity
Electrical Requirements
This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
All wiring should conform to Local and NEC codes.
This range requires a single-phase, 3 wire, A.C
120/208 V or 120/240 V 60 Hz electrical system. Use
only a 3-conductor or a 4-conductor UL- listed range
cord with closed-loop terminals, open-end spade lugs
with upturned ends or similar termination. Do not install
the power cord without a strain relief.
A range cord rated at 40 amps with 120/240
minimum volt range is required. If a 50 amp range
cord is used, it should be marked for use with 1
3
/
8
"
diameter connection openings. This appliance may
be connected by means of a conduit or power cord.
If a conduit is being used, go to page 21 for 3 wire
conduit connections or 4 wire conduit connections.
WARNING
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack
in the line so that the range can be moved if
servicing is ever necessary.
The power supply cord and plug should
not be modified. If it will not fit the outlet,
have a proper outlet Installed by a qualified
electrician.
Using an extension cord to connect the
power is prohibited. Connect the power
cord and plug directly.
Electrical ground is required on this appliance.
Make sure that the power cord is not pinched
by the range or heavy objects. Failure to do so
can result in serious burns or electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified
rating of
power
supply-
cord kit,
amperes
Diameter (inches)
of Range
connection
Opening
120/240
volts
3-wire
120/208
volts
3-wire
Power
cord
Conduit
8,750 -
16,500
16,501 -
22,500
7,801 -
12,500
12,501 -
18,500
40 or 50A
50
1
3
/
8
"
1
3
/
4
"
1
1
/
8
"
1
3
/
8
"
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord
The rear access cover must be removed. Loosen the
two screws with a screwdriver. The terminal block will
then be accessible.
Access cover
Use the cord/conduit connection plate to install the
power cord or conduit. Leave the connection plate
as installed for power cord installations. Remove the
connection plate for conduit installations and use the
smaller 1
1
/
8
in. (2.8 cm) conduit hole instead of the
1
3
/
8
in. (3.5 cm) power cord hole.
Remove the conduit connection plate
1
1
/
8
"
(2.8 cm) Conduit
1
3
/
8
"
(3.5 cm) Cord
For power cord installations, hook the strain relief
over the 1
3
/
8
in. (3.5 cm) power cord hole located
below the rear of the oven. Insert the power cord
through the strain relief and tighten it.
Conduit
connection
plate
Power cord
Assembling power cord strain relief at the 1
3
/
8
" opening
For conduit installations, insert the conduit strain
relief in the 1
1
/
8
in. (2.8 cm) conduit hole. Then install
the conduit through the body of the strain relief and
fasten the strain relief with its ring.
Cord/
Conduit
connection
plate
Conduit
Ring
Body
Assembling conduit cord strain relief at the 1
1
/
8
" opening