TROUBLESHOOTING
Fault
Solution
Light on, but motor
does not work
Remove the source of
the blockage
Contact Omega
Service
Contact Omega
Service
Contact Omega
Service
Light does not work,
motor does not work
Beside the above mentioned, check the following:
Light damaged/No lights
Replace lights
Power cord loose
Contact Omega Service
Oil leakage
One way valve and the air
ventilation entrance are not
tightly sealed
Take down the one way
valve and seal with
silicone rubber.
Leakage from the
connection of U-shaped
section and cover
Take U-shaped section
down and seal with
silicon or paint
Shake of the body
The fan is damaged and
causes shaking
Replace the fan
The motor is not tightly
mounted
Lock the motor mounts
tightly
The body is not tightly hung
on wall
Fix the body tightly
Insufficient suction
The distance between the
body and the gas top too
long
Readjust the distance
Too much ventilation or
breeze from open doors or
windows
Choose a better location
and re-assemble the
machine
The machine inclines
The fixing screw not tight
enough
Tighten the hanging
screw and make it
horizontal
The hanging screw not tight
enough
Tighten the hanging
screw and make it
horizontal
Loading ...