Periodic Maintenance
If the water drain valve (with water lter) is covered with debris, the hot water may not run
smoothly, or the unit may put out cold water. Check and clean the lter as explained below.
* To avoid burns, wait until the equipment cools down before draining the water.
The appliance will remain hot after it is turned off.
Water Drain Valve (with Water Filter)
1. Close the water supply valve.
2. Open all hot water xtures.
3. With a bucket ready, remove the inlet and outlet
drain plugs (For EN18WI30LS and EP18WI30LS,
about 0.4 gallon (1.4L) will drain out.
For EN19WI30LS and EP19WI30LS,
about 0.45 gallon (1.7L) will drain out.)
4. Take the water drain valve (with water lter) out of
the inlet. (See illustration to right).
5. Clean the water drain valve (with water lter) with
a brush under running water.
6. Replace the water drain valve (with water lter)
and close the drain plugs.
(Take care not to lose the packing.)
7. Close all hot water xtures.
8. Open the water supply valve and check that
water does not leak from the drain plugs or water
drain valve (with water lter).
Optional Maintenance
* Isolation valves may be purchased as an
accessory from Electrolux.
They allow for full diagnostic testing and easy
ushing of the system.
* The kit includes two full port isolation valves
and a pressure relief valve for the hot side.
Contact Electrolux for more information.
Isolation Valves
Water Supply
Valve
Inlet
Packing
Water drain valve
(with water lter)
Water Intlet
Water Outlet
Drain
Hot Water
Service Valve
Pressure Relief Valve
Cold Water
Service Valve
(Ex. EN18WI30LS)
(Ex. EN18WI30LS)