Operations
Operations
06 Filter Reset (3 sec)
Filter Reset
After about 6 months of using the original water lter (which typically
amounts to about 300 gallons (1136 liters) of water), the Filter
indicator blinks red to remind you that the lter needs to be replaced.
When this happens, replace the lter, and then press and hold Filter
Reset for 3 seconds. This resets the lter lifecycle detector and turns
off the Filter indicator.
NOTE
Some areas have relatively large amounts of lime in their water.
This may reduce the lifecycle of the lter. In these areas, you will
have to replace the water lter more often than specied above.
If water is not dispensing properly, the water lter is most likely
clogged. Even if the Filter indicator is not blinking, replace the
water lter.
07 Deodorizer Reset (3 sec)
Deodorizer
Reset
After about 18 months of using the original deodorizer lter, the Filter
indicator blinks red to remind you that the lter needs to be replaced.
If this happens, replace the lter, and press and hold Deodorizer Reset
for 3 seconds. The lter lifecycle will be reset and the Filter indicator
turns off.
08 Door Alarm / °C °F (3 sec)
Door Alarm
You can enable or disable the door alarm by pressing Door Alarm.
When Door Alarm is enabled and a door is left open for more than 2
minutes, the alarm will sound and the alarm indicator will blink. The
Door Alarm function is enabled by factory default.
°C °F
You can use the Door Alarm button to switch the temperature scale
between Celsius and Fahrenheit.
To switch the temperature scale, press and hold Door Alarm for
3 seconds.
09 Override (3 sec)
Override
The Override function activates/deactivates Smart Grid.
Press Override for 3 seconds to set/clear the Override function.