7
Remove the bottom grill from the cabinet to clean the condenser coil. It is located behind
the grill. Use a soft bristled brush to remove any dirt particles that are on the fins of the
condenser coil. After this, use a vacuum cleaner or compressed air to remove the
loosened particles. Replace the bottom grill and plug in the unit to outlet. Failure to clean
the condenser coil can lead to performance loss and compressor failure.
6. Wait at least 5 minutes after unplugging the unit before plugging it in again.
7. The pressure relief filter is in the filter bracket which is located in the top of AFS, ARS
and ARG models. The filter should be checked monthly and cleaned with a soft brush
when necessary. If the filter is clogged, it would take more time to open the door again.
Alarm Function for Cleaning Condenser
1. This function reminds the customer that the condenser cleaning time is every 6 months.
Dust piled up on the condenser pin can cause poor refrigeration function and
compressor overload or failure. Be sure to clean it periodically.
Reminder of cleaning time: When the buzzer sound continues for 1hour, “CL” on the
display blinks.
Releasing alarm: Press “Mode” and “Verify” buttons at the same time for 5 seconds,
The buzzer stops and “CL” disappears. The current temperature appears on the
display.
2. In case no action is taken to release the alarm (such as absence):
Buzzer: will stop automatically after 1 hour of continuous alarm sound
Display: will keep blinking “CL” until the compulsive release
OPERATION
A. BASIC OPERATION
1. If you plug in and turn on the power switch, the display panel will light for 2 seconds
followed by a beeping sound. Then, cabinet temperature will be displayed.
2. If cabinet temperature is higher than -5°C (freezer models), or 14°C (refrigerator
models), the panel displays [Hi]. If the reading is lower than-40°C (freezer models), or
-2°C (refrigerator models), the panel displays [Lo].
3. The power switch is located in the right side of top grille.
4. Compressor operation and defrost function are controlled by the electronic controller.
5. The light inside the cabinet turns on when the door is opened.
6. The light switch for glass-door models is located next to the power switch in the right
side of the top grille.