Burner and nozzle characteristics tables
1 Natural Gas G20 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
72 97 120 75+135
Pre-chamber (printed on nozzle)
(X) (Z) (H9) (H1)+(H3)
Reduced flow rate (W)
400 500 800 1900
2 Natural Gas G20 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
72 94 113 75+127
Pre-chamber (printed on nozzle)
(X) (Z) (H8) (H1)+(H3)
Reduced flow rate (W)
400 500 800 1900
3 Natural Gas G25 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.8 4.0
Nozzle diameter (1/100 mm)
72 94 120 75+135
Pre-chamber (printed on nozzle)
(X) (Y) (H9) (H1)+(H3)
Reduced flow rate (W)
400 500 800 1900
4 Natural Gas G25.1 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
77 100 134 75+138
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (H1)+(F3)
Reduced flow rate (W)
400 500 800 1900
6 Natural Gas G27 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
77 105 138 80+148
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (H1)+(F3)
Reduced flow rate (W)
400 500 800 1900
7 Natural Gas G2.350 AUX SR R UR2 (int+ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.0
Nozzle diameter (1/100 mm)
94 120 165 100+190
Pre-chamber (printed on nozzle)
(Y) (Y) (F3) (0)+(H3)
Reduced flow rate (W)
400 500 800 1900