Loading ...
Loading ...
Loading ...
Connecting the Water Supply
_ WARNING
To avoid electric shock, which can
cause death or severe personal injury,
disconnect the refrigerator from electrical
power before connecting a water supply
line to the refrigerator.
_ CAUTION
To Avoid Property Damage:
Copper or Stainless Steel braided tubing
is recommended for the water supply
line. Water supply tubing made of
inch plastic isnat recommended to be
used. Plastic tubing greatly increases
the potential for water leaks, and the
manufacturer will not be responsible far
any damage if plastic tubing isused far
the supply line.
DO NOT install water supply tubing
in areas where temperatures fall
below freezing.
Chemicals from a malfunctioning
softener can damage the ice maker.
If the ice maker is connected to soft
water, ensure that the softener is
maintained and working properly.
IMPORTANT
Ensure that your water supply line
connections comply with all local
plumbing codes.
Before InstallingThe Water Supply Line,
YouWill Need:
* Basic Tools: adjustable wrench, fiat-blade
screwdriver, and Phillips TM screwdriver
* Access to a household cold water line with
water pressure between 30 and 100 psi.
* A water supply line made of t/4 inch
(6.4 ram) OD_ copper or stainless steel
tubing. To determine the length of tubing
needed, measure the distance from the
ice maker inlet valve at the back of the
refrigerator to your cold water pipe. Then
add approximately 7 feet (2.1 meters),
so the refrigerator can be moved out for
cleaning (as shown).
A shutoff valve to connect the water
supply line to your household water
system. DO NO]" use a self-piercing type
shutoff valve.
* Do not reuse compression fitting or use
thread seal tape.
* A compression nut and ferrule (sleeve) for
connecting a copper water supply line to
the ice maker inlet valve.
NOTE
Check with your local building authority
for recommendations on water lines and
associated materials prior to installing
your new refrigerator.
To Connect Water Supply Line To Ice Maker
Inlet Valve
1.
2.
3.
4.
Disconnect refrigerator from electric
power source.
Place end of water supply line into sink
or bucket. Turn ON water supply and
flush supply line until water is clear. Turn
OFF water supply at shutoff valve.
Remove plastic cap from water valve
inlet and discard cap.
If you use copper tubing - Slide brass
compression nut, then ferrule (sleeve)
onto water supply line. Push water
supply line into water valve inlet as far
as it will go (1/4inch/6.4 ram). Slide
ferrule (sleeve) into valve inlet and finger
tighten compression nut onto valve.
Tighten another half turn with a wrench;
DO NOT overtighten. See Figure 1.
If you use stainless steel tubing - The
nut and ferrule are already assembled
on the tubing. Slide compression nut
onto valve inlet and finger tighten
compression nut onto valve. Tighten
another half turn with a wrench; DO
NOT overtighten. See Figure 2.
15
Downloaded from www.ManualsFile.com manuals search engine
Loading ...
Loading ...
Loading ...