Loading ...
Loading ...
Loading ...
Installation
22
5. The two rear screws need to be removed
only on 70 cm models.
6. Remove the top.
Replacing nozzles
1. Unscrew screw A and push air regulator
B as far as it will go.
2. Use a spanner to remove the nozzles C
and install the new ones for the required
gas supply, following the indications
given in the relevant table (see “Burner
and nozzle characteristics tables”).
3. Adjust the air flow by moving the air
regulator B to obtain the distance D
given in the relevant table (see “Burner
and nozzle characteristics tables”).
4. After adjusting each burner, reassemble
the appliance correctly.
The nozzle tightening torque must
be no more than 3 Nm.
Loading ...
Loading ...
Loading ...