Instructions for the installer
45
9.6.2 Adjusting the minimum setting for LPG
To adjust the minimum setting with LPG, you must tighten the screw inside or next to
the tap rod (depending on the model) fully in a clockwise direction.
The bypass diameters for each individual burner are shown in table “9.2 Adjustment
for LPG”.
After adjustment with a gas other than the preset one, replace the label on the
casing of the appliance with the label corresponding to the new gas. The label is
inserted inside the pack together with the nozzles.