KitchenAid MGDZ400TF laundry

User Manual - Page 11

For MGDZ400TF.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
11
Optional exhaust installations
Exhaust Cover Kit (to cover unused exhaust holes):
Part Number W10186596 - all models
This dryer can be converted to exhaust
out the right side, left side or
through the bottom. If you prefer, you may contact your local dealer
to have the dryer converted.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manuf
acturer’s instructions.
A B
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the “Assistance or Service”
section to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special provisions for mobil
e home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the m
obile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct
path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best
drying performance
Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE:
Do not use vent runs longer than those specified in the
Vent system chart.
Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting r
equirements that will help
to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn inside
the dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Bends or
90º elbow
s
Type of vent Box or Louvered
hoods
Angled hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Loading ...
Loading ...
Loading ...