Miele DA3496 90cm Under Cupboard Rangehood

User Manual - Page 38

For DA3496.

PDF File Manual, 48 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation
38
Set up for recirculation mode
If site conditions are not suitable for the
r
angehood to be used with air
extraction, the appliance must be set
up for recirculation. The DUU 151
conversion kit, available from Miele, is
required for operating the rangehood in
recirculation mode. You will also need a
charcoal filter (see "Technical data").
When using the rangehood in
r
ecirculation mode, a non-return flap is
not fitted. Depending on the model of
rangehood, the non-return flap may
already be fitted.
Remo
ve the non-return flap from the
exhaust connection.
Fit the conversion kit as described in
the installation instructions supplied
with the kit. Mak
e sure that the slats
in the exhaust grille point towards the
centre of the room and not towards a
wall or the ceiling.
A non-return flap is not used in
recirculation mode.
Fi
t the charcoal filter (see "Cleaning
and care").
Loading ...
Loading ...
Loading ...