CLEARANCE FROM COMBUSTIBLES
SAVE THIS MANUAL FOR FUTURE REFERENCE
For Wall-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm) from
ceiling and do not install less than 6' (1.8m) if the heater is labeled as UL Listed and 8' (2.4m) if the heater is
labeled as UL/CUL Listed from floor, while heater is set at a downward angle of 30 to 60 degrees.
For Ceiling-Mounting, do not install heater closer than 18" (45.7cm) from adjacent walls and 6" (15.2cm)
from ceiling and do not install less than 6' (1.8m) if the heater is labeled as UL Listed and 8' (2.4m) if the
heater is labeled as UL/CUL Listed from floor, while heater is at a maximum 30 degrees.
Adjacent Heaters to be installed no less than 3' (0.9m) apart.
Do NOT operate within 25' (7.6m) of flammable/explosive material.
Never block heater.
Heaters greater than 240 Volts are for “Commercial Use Only. Risk of fire. Do not use as a residential or
household heater.”
A means for disconnection of the appliance must be incorporated in accordance with the local wiring codes.
Do not use if the heating element is damaged or cracked.
CLEARANCE FROM COMBUSTIBLES:
MIN. 18" (45.7cm)
FROM SIDES AND
ENDS OF HEATER
MIN. 36" (91.4cm)
IN FRONT OF HEATER
MIN. 6" (15.2cm)
CLEARANCE
BEHIND HEATER
“IMPORTANT INSTRUCTIONS”
“SAVE THESE INSTRUCTIONS”
WARNINGS- Read all instructions before using heater:
Unit may be a source of possible shock. NEVER attempt to service heater without disconnecting its power source. Source
of possible ignition.
CAUTION-High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3'
(0.9m) from the front of heater and away from sides and rear.