14 | Sub-Zero Customer Care 800.222.7820
TECHNICAL DATA
Sub-Zero Water Filtration System Data
IMPORTANT NOTICE: Read this Performance Data Sheet carefully and compare the capabilities of this unit with your actual water treatment needs.
It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system, as specied in NSF/ANSI 42/53.
System tested and certied by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of substances listed below.
Contaminant
Reduction*
Average Inuent
Concentration
NSF Specied
Challenge
Concentration
Average
% Reduction
Product Water Concentration
NSF Reduction
Requirements
NSF Test
ReportAverage Max Permissable
Chlorine, Taste & Odor 2.0 mg/L 2.0 mg/L ± 10% 97.5% 0.05 mg/L N/A ≥50% J-00056501
Normal Particulate
Class I, ≥0.5 to <1.0 μm
13,666,667
pts/ml
At least 10,000
particles/ml
98.9% 143,333 pts/ml N/A ≥85% J-00056506
Asbestos 96 MF/L 10
7
to 10
8
bers/L
>99% <1 MF/L N/A ≥99% J-00056511
Atrazine 0.010 mg/L 0.009 mg/L ± 10% 89.3% 0.001 mg/L 0.003 mg/L N/A J-00056512
Benzene 0.014 mg/L 0.015 mg/L ± 10% 96.3% 0.005 mg/L 0.005 mg/L N/A J-00056535
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 86.6% 0.01 mg/L 0.04 mg/L N/A J-00056537
Cyst** 122,500 cysts/L Min 50,000 cysts/L 99.99% 1 cyst/L N/A ≥99.99% J-00056513
Lead at pH 6.5 0.153 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00056515
Lead at pH 8.5 0.150 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00058784
Lindane 0.002 mg/L 0.002 mg/L ± 10% 97.8% 0.00004 mg/L 0.0002 mg/L N/A J-00058969
Mercury at pH 6.5 0.006 mg/L 0.006 mg/L ± 10% 95% 0.0003 mg/L 0.002 mg/L N/A J-00058785
Mercury at pH 8.5 0.006 mg/L 0.006 mg/L ± 10% 88% 0.0007 mg/L 0.002 mg/L N/A J-00058783
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-00056531
Turbidity 10.8 NTU 11 ± 1 NTU 98.7% 0.153 NTU 0.5 NTU N/A J-00058972
P-Dichlorobenzene 0.215 mg/L 0.225 mg/L ± 10% 99.7% 0.0005 mg/L 0.075 mg/L N/A J-00056538
*Contaminant reduction determined by NSF testing. **Based on the use of Cryptosporidium Parvum oocysts.
Fibers greater than 10 μm in length.
APPLICATION GUIDELINES / WATER SUPPLY PARAMETERS
Capacity: certied for up to 750 gallons
(2,839 L); up to twelve months
Service Flow: 0.78 gpm
(2.95 Lpm)
Water Supply: potable water
Water Pressure: 35–120 psi
(2.8–8.2 bar)
Water Temperature: 40°F–100°F (5°C–40°C)
SPECIAL NOTES
Replacement Sub-Zero water lter cartridges can be ordered online at subzero.com/store, or contact customer care at 800-222-7820.
It is recommended that the lter cartridge be replaced when the indicator is displayed, if there is a noticeable drop in pressure, the ice cubes
become hollow, or every 12 months, whichever comes rst. Replacement lter pricing information can be found at subzero.com/store.
This lter must be installed, operated, maintained and replaced as required in order for the product to perform as advertised.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. The contaminants or other
substances removed or reduced by this water treatment system are not necessarily in your water.
Manufactured for: Sub-Zero, Inc., P.O. Box 44848, Madison, WI 53744, 800-222-7820