Procom MNSD3TPA-BB Heating

User Manual - Page 4

For MNSD3TPA-BB. Also, The document are for others Procom models: MD2TPA, MD3TPA, MD5TPA, MD3TPA-BB, MD5TPA-BB

PDF File Manual, 72 pages, Read Online | Download pdf file

MNSD3TPA-BB photo
Loading ...
Loading ...
Loading ...
www.usaprocom.com
200042-01B4
1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters 10,000 Btu/Hr or more shall not
be installed in a bedroom or bathroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See Air
for Combustion and Ventilation, pages
7 through 9. If heater keeps shutting off,
see Troubleshooting, page 22.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
Where ammable liquids or vapors are
used or stored.
Under dusty conditions.
SAFETY
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
8. Always run heater with control knob at
PILOT/IGN, LOW (1) or HIGH (5) locked
positions. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
9. Do not use heater if any part has been
under water. Immediately call a qualied
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off and unplug heater and let cool
before servicing. Only a qualied service
person should service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lbs. capacity.
MODEL MD2TPA MD3TPA MD5TPA
Ignition Electric Piezo Electric Piezo Electric Piezo
Gas Type Natural Gas Natural Gas Natural Gas
BTU (available) 12,000 20,000 30,000
Pressure Regulator Setting 6" W.C. 6" W.C. 6" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 10.5" Maximum 10.5" Maximum 10.5"
Minimum 7" Minimum 7" Minimum 7"
Gas Type Propane Gas Propane Gas Propane Gas
BTU (available) 10,000 18,000 26,000
Pressure Regulator Setting 10" W.C. 10" W.C. 10" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 14" Maximum 14" Maximum 14"
Minimum 11" Minimum 11" Minimum 11"
Heater Dimensions (HxWxD)
19
1
/
8
" × 14
1
/
8
" ×
7
1
/
8
"
23
1
/
2
" × 19
1
/
4
" × 8
3
/
4
"
23
1
/
2
" x 26
5
/
8
" x 8
3
/
4
"
Carton Dimensions (HxWxD)
22 ×16
3
/
4
" × 8
7
/
8
" 25
3
/
4
" × 21
3
/
4
" × 10" 25
3
/
4
" x 28
1
/
2
" x 10"
Heater Weight 15.1 lbs 21.6 lbs 28.1 lbs
Shipping Weight 18.1 lbs 25.6 lbs 33.1 lbs
SPECIFICATIONS
Loading ...
Loading ...