26
CARE AND USE/INSTALLATION
DRAIN PUMP REMOVAL INSTRUCTIONS
Additional issues to be inspected by the installer
upon service replacement:
1. The drain pump must be level.
2. No pinched water lines.
3. No interference with electrical cords or wiring.
4. The drain pump should not set on any obstacles,
wiring, etc.
5. Secure all hose clamps leading to and from the
drain pump.
6. Insure that the vent tube height is adequate - 18
inches minimum.
7. Insure that drain height is adequate - maximum
of 8 feet.
8. Insure that drain length is adequate - maximum
of 20 feet.
9. Checked for water leaks after installation of the
drain pump.
10. Check for vibrations caused by improper
installation.
11. Insure that there is no interference with back
access cover.
12. Insure that the hole grommets are in place at
each location so that any vent or drain tubes do
not rub on any sharp surfaces.
Ice machine
power cord
Figure 41
Rotate drain pump and
remove from back of
ice machine.
Figure 40
6. Rotate the drain pump and remove from the ice
machine, (See Figure 40). It may be necessary to
disconnect the ground wire connection in the back
ange of the cabinet. (See Figure 36).
7. Disconnect the ice machine power cord from the drain
pump (See Figure 41).
8. Drain the water in the drain pump’s reservoir by turning
the pump upside down and allowing water to drain
through the pump’s inlet and vent tube ttings.