L1
L2
L3 N1 N2
N
220-240V ~ / 50/60 Hz
N
L1
L2
L3 N1
N2
220-240V ~ / 50/60 Hz
2N 380-415V
N1
L1
L2
L3 N1 N2
3N 380-415V
L3
L1
L2
L3 N1 N2
N1
2 2N 220-240V ~ / 50/60 Hz
N2
N1
L1
L2
L3 N1
N2
CONNECTION DIAGRAM:
Jumpers (connecting bridges) are placed in the dedicated slot on
the clamp.
POWER CORD
The following may be used for connection:
PVC insulated connection cables type H05 VV-F or H05V2V2-F
with yellow-and-green protective conductor, or other equivalent
or superior cables.
Exterior cable diameter should be at least 8.00 mm.
Normal connection
2 phases, 1 neutral conductor (21N, 380-415V~/50/60 Hz):
Voltage between phases and neutral conductor is 220-240V~.
Voltage between the two phases is 380-415 V~. Install a jumper
between the terminals 4–5. The group should include at least
two 16-ampere fuses. Diameter of the power cord core should
be at least 2.5mm
2
.
2 phases, 2 neutral conductors (22N, 220-240V~/50/60 Hz):
Voltage between phases and neutral conductors is 220-
240V~.
The group (installation) should include at least two 16-ampere
fuses. Diameter of the power cord core should be at least
2.5mm
2
.
Special connection:
Single-phase connection (11N, 220-240V~/50/60 Hz):
Voltage between phase and neutral conductor is 220-240V~.
Install jumpers between the terminals 1–2 and 4–5. The group
(installation) should be fitted with a fuse of at least 32A.
Power cord core diameter should be at least 4mm
2
.
Run the power cord through a cord strain relief (clamp) which
protects the cable from being pulled out. Make sure the cable on
the rear side of the appliance is not in contact with the cooking
hob rear wall, as this part can heat up during use.
After connecting the appliance, switch on all heaters for
approximately 3 minutes to check their operation.
False connection can destroy parts of the appliance. In such case,
there is no right to warranty.
Before connecting the appliance, make sure the voltage specified
on the rating plate conforms to the voltage of the power mains.
An expert should check the actual voltage in your home (220-
240V relative to N), using a suitable meter!
48
799434