33
Trouble shooting
Malfunction Cause Remedial action
ADD 8EanS
is
displayed despite a full
bean container.
Grinder has still not been
filled automatically.
Press the
n
buton.
The beans are too big or too
oily – they do not slide into
the grinding unit.
Use less oily or smaller beans.
To remove big beans use
a vacuum cleaner.
No hot water or steam
discharge.
Nozzle is blocked. Thoroughly clean nozzle.
Froth insufficient or too
runny.
Sleeve
a
on nozzle
12
not in
correct position.
Push down sleeve
a
on
nozzle
12
.
Unsuitable milk. Use cold semi-skimmed milk.
Coffee is running a drop at
atime.
Degree of grinding too fine. Select a coarser degree of
grinding.
The beans are too oily. Use less oily beans.
Preground coffee too fine. Use a coarser ground coffee.
To rinse the appliance, follow
the instructions “Using ground
coffee” on page 16, but do not
add coffee powder in the duct.
Coffee has no “crema”
(layer or froth).
Unsuitable type of coffee. Change the type of coffee.
Beans no longer fresh. Use fresh beans.
Degree of grinding not
appropriate for coffee beans.
Optimize degree of grinding.
Grinding unit is not grinding
coffee beans.
Beans are not falling into the
grinding unit (too oily).
Gently tap the bean container.
Descaling program does
not start.
Current programming set to
filter yes/new
or
change filter
display.
Set programming to
filter no/old
.
Before descaling the appliance,
always remove the filter!
System too hot. Draw off some of the hot water.
Cleaning program does
not start.
System too hot. Draw off some of the hot water.
filter change
displayed.
Change filter.
Loading ...