 49-5000561 Rev. 2
Troubleshooting Tips... Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem Possible Cause What To Do
The unit does not function
after installing Remote
Wall Thermostat
Unit thermostat connections are incorrect. 9HULI\ZLULQJIURP5HPRWH:DOO7KHUPRVWDWLVFRUUHFWWRXQLW
thermostat connector.
7UDQVIRUPHUUHVHWVRURSHQVZLWKVKRUW Wait 5 minutes to see if power resets.
Heat pump operates with
electric heat only during
heating.
Outdoor ambient temperature is too cold. Heat pump operation will not function if the outdoor ambient
temperature is too cold. Heat pump will resume once the
outdoor temperature has sufficiently warmed up
$X[0RGHQRWVHWSURSHUO\ 6HH³6HWWLQJWKHDX[LOLDU\FRQWURO´VHFWLRQRIWKLVPDQXDO
&KHFN$X[0RGHWREHVXUHWKHPRGHLVVHWWROFF³8´IRU
heat pump operation.
TROUBLESHOOTING TIPS
FAULT CODES - Press and hold MODE, then press AUX
7KLVVKRZVDOOFXUUHQWIDXOWFRGHVDQGF\FOHVWKURXJKWKHP,IWKHUHDUHQRFXUUHQWIDXOWVWKHGLVSOD\VKRZV
3UHVVLQJ$8;FOHDUVWKHIDXOWV$Q\RWKHUNH\H[LWVDQGSUHVHUYHVWKHIDXOWV
Fault Code
Numbers
Fault Meaning Effective on system operation while
fault is active
,QVLGHIDQIDXOW)DQPRWRUQRWPRYLQJDWFRPPDQGHGVSHHGDIWHU
VHFRQGVRIGULYH)DXOWFOHDUVDIWHUPLQXWHV
1RUHVLVWDQFHKHDWLQJIDQKHDWLQJ
pump or cooling available.
2 2XWVLGHIDQIDXOW)DQPRWRUQRWPRYLQJDWFRPPDQGVSHHGDIWHU
VHFRQGVRIGULYH)DXOWFOHDUVDIWHUPLQXWHV
1RKHDWSXPSRUFRROLQJDYDLODEOH
Resistance heating and fan only.
3 ([WHUQDOWKHUPRVWDWZLULQJ$SSOLHGVLJQDOLVQRWYDOLGDQGKDVEHHQ
FRQVWDQWIRUVHFRQGV
1RH[WHUQDOFRQWURORIIDQVKHDWDQG
cooling internal control operation only.
,QVLGHWKHUPLVWRUIDXOW2QHRIWKHLQVLGHWKHUPLVWRUVLVQRWUHDGLQJYDOLG
temperatures.
1RFRROLQJRUKHDWSXPSRSHUDWLRQDYDLODEOH
Resistance heating and fan only.
5 Outside thermistor fault.
One of the outside thermistors is not reading valid temperatures.
1RFRROLQJRUKHDWSXPSRSHUDWLRQDYDLODEOH
Resistance heating and fan only.
&RPSUHVVRUIDXOW1RWHPSHUDWXUHFKDQJHKDVEHHQGHWHFWHGDIWHU
minute of running.
1RHIIHFW
7 5HYHUVHYDOYHIDXOW7HPSHUDWXUHFKDQJHQRWKDSSHQLQJDVH[SHFWHG
DIWHUPLQXWHRIUXQQLQJ
1RFRROLQJRUKHDWSXPSRSHUDWLRQDYDLODEOH
Resistance heating and fan only.
8 Software fault. Stack overflow. 1RHIIHFW
,QGRRUFRLOIUHH]HIDXOW7KHWHPSHUDWXUHRIWKHLQVLGHFRLOKDVIDOOHQ
EHORZWKHIUHH]HWKUHVKROG)
7KHFRPSUHVVRULVVKXWGRZQXQWLOWKH
coil temperature recovers.
 +HDWSXPSRYHUORDGIDXOW7KHLQVLGHFRLOWHPSHUDWXUHLVRYHUWKH
RYHUORDGWKUHVKROG)
7KHFRPSUHVVRULVVKXWGRZQZKLOHWKH
coil temperature recovers.
2YHUKHDWIDXOW7KHLQFRPLQJDLULVWRRKRWWRUXQWKHKHDWHU Heat pump and resistance heating are
shut down and restarted when the indoor
ambient temperature cools sufficiently.
 8,ERDUGGLVFRQQHFWHGIDLOHG 1RHIIHFW
 Heater airflow fault. 1RUHVLVWDQFHKHDWLQJDYDLODEOH
 1$ 1$
 Outlet thermistor failure. Fault clears when thermistor reads value other
than short circuit or open circuit.
1RUHVLVWDQFHKHDWLQJDYDLODEOH
 2XWOHWWHPSHUDWXUHRYHUKHDW7KHRXWJRLQJDLULVWRRKRW)DXOWFOHDUV
when air temperature drops below threshold.
1RUHVLVWDQFHKHDWLQJDYDLODEOH
 2XWOHWWHPSHUDWXUHRYHUKHDW7KHRXWJRLQJDLULVWRRKRW 1RUHVLVWDQFHKHDWLQJDYDLODEOH
23 1$ 1$
 1$ 1$
25
$EQRUPDO'HIURVW)DXOWKHDWSXPSPRGHOVRQO\6HWZKHQFRQVHFXWLYHGHIURVW
F\FOHVIDLOHGWRZDUPRXWGRRUFRLODERYH):LOOVHOIFOHDUDIWHUGD\V
Locks out heat pump, locks out defrost.

Air Conditioning Lockout Fault. Sets when outdoor ambient temperature drops
EHORZ):LOOVHOIFOHDUDIWHU2XWGRRU$PELHQWWHPSHUDWXUHULVHVDERYH)
Locks out compressor cooling operation.