Loading ...
Loading ...
Loading ...
32
ELECTRONIC CONTROL SETUP INSTRUCTIONS (PR/PD models)
Code Explanation
J. Cd PAYMENT MODE (COIN/DEBIT OPTION)
J. Cd Both coin and debit selected. Press the DELICATES
button 3 consecutive times to change this selection.
J. C_ Coins selected, debit disabled. Press the DELICATES
button 3 consecutive times to change this selection.
J._d Debit Card selected, coins disabled. Press the
DELICATES button 3 consecutive times to change this
selection.
J. Ed Enhanced Debit is self-selected when a Generation 2
card reader is installed in the dryer. The Ed option cannot
be manually selected or deselected.
Press the NORMAL button once to advance to next
code.
L. 00 PRICE SUPPRESSION OPTION
This option is either NOT SELECTED “OFF” or
SELECTED “ON.” This option causes the customer
display to show “ADD” or “AVAILABLE” rather than
the amount of money to add. (Used mainly in debit
installations.)
L. 00 Not Selected “OFF.
L. PS Selected “ON.
Press the DELICATES button once to change this
selection.
Press the NORMAL button once to advance to next
code.
n. CE CLEAR ESCROW OPTION
This option is either NOT SELECTED “OFF” or
SELECTED “ON.” When selected, money held in escrow
for 30 minutes without further escrow or cycle activity will
be cleared.
n. 00 Not Selected “OFF.
n. CE Selected “ON.
Press the DELICATES button once to change this
selection.
Press the NORMAL button once to advance to next
code.
u.00 PENNY INCREMENT OFFSET
u.00 This represents the penny increment price offset used in
Generation 2 (Enhanced Debit) PR models. Choose from
0–4 pennies by pressing the WHITES AND COLORS
button.
Press the NORMAL button once to advance to next
code.
END of SET-UP PROCEDURES
EXIT FROM SET-UP MODE
Single-Load PD Models: Reinstall access door.
Single-Load PR Models:
g Unplug dryer or disconnect power.
g Open console, reinsert plug into AA1, close console.
g Plug in dryer or reconnect power.
DIAGNOSTIC GUIDE
If the set-up mode is entered and one of the following has
occurred, the appropriate diagnostic code will be in the display.
SINGLE DRYERS
CODE EXPLANATION
d1 Dryer door sense error on
control board or due to power
line interference (cycles and
price display disabled until
diagnostic code is manually
cleared).
d4 Dryer motor control circuit error
(cycles and customer display
disabled until diagnostic code is
manually cleared).
d5 Blocked coin 1 or coin drop
control circuit failure (coin
recognition and customer
display disabled while blockage
persists).
d9 Voltage detected below
90 VAC for 8 seconds.
d12 Motor sense error on control
board or due to power line
interference (cycles and
customer display disabled until
diagnostic code is manually
cleared).
d13 Blocked coin 2 or coin drop
control circuit failure (coin
recognition and price display
disabled while blockage
persists).
d16 Not receiving communications
from installed debit card reader
in Enhanced (Generation 2)
Debit mode.
Loading ...
Loading ...
Loading ...