36 Part Number: 000015430 Rev 02 5/20
Heat of Rejection
Model Peak Average
IF0500N IT0500N 3800 6000
IF0600 11800 13000
IF0900/IT0900 13000 16000
IT1200N 16200 19100
IT1500N 23000 27000
IT1900N 26100 30500
Refrigerant Charge
The ice machine model/serial tag lists the refrigerant
amount. Remote condensers and line sets contain a vapor
charge only.
Quick Connect Fittings
The ice machine and line sets come with quick connect
fittings. It is recommended that matching quick connects
(available through Manitowoc Distributors K00129) be
installed in the multi-circuit condenser, and that a vapor
“holding” charge, 5 oz. (150 ml), of proper refrigerant be
added to the condenser prior to connection of the ice
machine or line set to the condenser.