6:1
The machines software provides a “Service Mode” (SM) to adjust operating parameters
and view usage statistics. The service mode also allows a technician to activate individual
components of the machine, for troubleshooting. The software also provides a “Limited Service
Mode” (LSM) that allows a technician to activate machine components, via PIN entry, without
having access to the coin vault service switch. If desired on machine setup, LSM via PIN entry
can be disabled or allowed to have full SM functionality without requiring access to the coin vault.
To activate Service Mode for machines with coin meters:
1. Remove the coin box.
2. Press and release the SERVICE MODE plunger switch at the rear of the coin vault. The
screen will display “8888.
3. Press the START button. “SE” appears in the display.
4. Use the HEAVY SOIL & EXTRA RINSE buttons to navigate to the desired register.
5. Press START to access the register or activate the function.
6. Use HEAVY SOIL & EXTRA RINSE to change values, as appropriate. Some registers
require using the COLD, WARM, and HOT, DELICATE buttons to edit settings.
7. Press START to save new values, as appropriate.
8. Press the SERVICE MODE switch to exit. SM exits automatically after 60 seconds of
inactivity with all service functions off.
For Non Metered machines, the SERVICE MODE plunger switch is located behind the front
console locking plate.
To activate Limited Service Mode:
1. Press and hold COLD, DELICATE, and START buttons for three seconds.
2. Use the program buttons to enter the PIN code (default is “1234”).
3. Press START. The display shows “011” (the rst register available in LSM).
4. Use the HEAVY SOIL & EXTRA RINSE buttons to navigate to the desired register.
5. Press START to access the register or activate the function.
6. Use HEAVY SOIL & EXTRA RINSE to change values, as appropriate.
7. Press START to save new values, as appropriate.
8. LSM exits automatically after 60 seconds of inactivity with all service functions off.
Service Mode Register Groups:
00-19 Statistics: These are non-resetable auditing counters and log registers for tracking
machine usage, the four latest errors, and the four latest coinbox opening time stamps.
20-39 Wash Program Parameters: These registers are used to adjust water levels and program
structure.
40-59 Activate Machine Functions: In this group, the register address appears in the rst two
digits of the display, and the current setting appears in the right digit (“0” = deactivated, “1” =
activated). Press the START button to toggle the state.
70-79 Real Time Clock, calendar, and time-of-day discount promotion setup: These registers set
up the internal clock, calendar, and promotion pricing.