SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required.
IMPORTANT NOTE: For indoor models, a ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
For the outdoor model, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
ELECTRICAL SUPPLY LOCATION
A
18" Model 6" (152)
24" Model 9
1
/2" (241)
27" Model 11" (279)
30" Model 12
1
/2" (318)
36" Model 15
1
/2" (394)
A
1
/4" (6)
1
/4" (6)
4
1
/4"
(108)
4
1
/2"
(114)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location.
CAUTION
The outlet must be checked by a qualied electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type