Anchor Types
Anchor Subfloor between unit and concrete 0”
to 1/2” (12.7mm) thick
Subfloor between unit and concrete
over 1/2” (12.7mm) thick
Static Imperial KH-EZ 1/4” x 4” KH-EZ 1/4” x 5”
Metric HUS-H 6mm x 120mm HUS-H 6mm x 150mm
Anchor Specifications
Static Anchor Minimum Concrete
Thickness
Minimum Drill Depth in
Concrete
Minimum Concrete
Embedment
Minimum concrete
compressive strength
KH-EZ 1/4” 4-1/8” (105mm) 1/2” (12.7mm) beyond
anchor length
2-1/2” (63.5mm) 3000psi (20 N/mm2)
HUS-H 6mm 3-3/32" (100mm) 25/64" (10mm) beyond
anchor length
2-1/64” (55mm) 3000psi (20 N/mm2)
Pullout Force
Cybex specifies Hilti
static and dynamic anchors. According to the anchor manufacturer, the recommended design pullout force (in
tension) for the specified anchors, when properly installed in cracked concrete, is provided in the side table. This table should be used
for reference only; for additional and up-to-date information on the anchor capabilities or the design pullout force in other substrates,
please consult Hilti directly at https://www.us.hilti.com.
Selected Anchor Design Resistance in Tension *
KH-EZ ¼” x 4” 830 lb
HUS-H 6MM x 120MM 3.3 kN
KH-EZ 3/8” x 4” 1535 lb
KH-EZ 3/8” x 5” 1535 lb
HUS-H 8MM x 120MM 3.3 kN
HUS-H 8MM x 150MM 3.3 kN
HSL-3 M 8/40 2000 lb
HST M12 x 115/20 8 kN
HST M12 x 195/200 8 kN
KB-TZ 3/8” x 3-3/4” 1615 lb
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.
Tools Required
WARNING: Adhere to manufacturer’s equipment warnings and guidelines. Follow manufacturer’s instructions for proper
usage.
Static Anchor
Floor scanner / rebar detector (optional)
1” L-shape SDS rotary hammer
1/4" x 12" (6mm x 305mm) carbide drill bit (for 1/4” (6mm)
anchors)
3/8" x 12" (8mm x 305mm) carbide drill bit (for 3/8” (8mm)
anchors)
Safety glasses
Extension cord
Impact wrench
Vacuum (for debris)