Jenn-Air UXL5430BSS

User Manual - Page 9

For UXL5430BSS.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
9
Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet. Mark the cutout as shown.
Use a saber saw or keyhole saw to cut a round opening
through the back of the cabinet and the exterior wall for
thevent.
Go to Step 3.
Non-Vented (recirculating) Installation Through
the Soffit/Cabinet
Measure and mark the centerline of the cabinet to the
softabove.
Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soft. Mark the
location and use a saber saw or keyhole saw to cut a 5
3
/
4
"
(14.6 cm) hole for the vent cover.
Measure and mark the centerline location for the cutout in
the cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
Cabinet Height Hole Shape and Size
12" (30.5 cm) A 6
1
/
4
" deep x 8" wide (15.9 cm x
20.3 cm) rectangular opening in the
cabinet top is required for damper
transition clearance.
15" (38.1 cm) cabinet
or soft installation
A 6
1
/
4
" (15.9 cm) diameter
roundopening is required.
18" (45.7 cm) or
24"(61.0 cm)
A 5
3
/
4
" (14.6 cm) diameter round
opening is required.
For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.
For non-vented (recirculating) installations, charcoal lters
are necessary. See the “Range Hood Care” section for
instructions on installing charcoal lters.
The Recirculation Kit Part Number W10490330 must
beused.
B
A
C
A. Measurement A
B. Centerline
C. 6
1
/
4
" (15.9 cm) round cutout
A
B
A. Vent cover
B. Centerline
D
A
B*
C
A. Cutout
B. *See chart below.
C. 7
3
/
4
" (19.7 cm) centerline to cabinet front
D. Centerline