CAUTION
When designing inlet and outlet, the following opening area shall be satisfied.
- Failure to do so may result in product problems, which are not warranted.
If a separate case is installed on the vessel, design it with the recommended opening area and aperture. Failure to
meet the recommended aperture plane and aperture ratio may cause the product to malfunction. In such cases, the
warranty does not apply.
NOTE
The partition should be in close contact with the case as well as with the enclosure when installed.
It is recommended that the inlet and outlet be located at the same position as the enclosure.
If possible, install ventilation openings around the inlet and outlet of the enclosure.
If you install both sides or multiple units together, you must increase the opening area by the number of installed
units.
Aperture plane
49XE4F 55XE4F
Air Inlet
8400 mm
2
8400 mm
2
Air Outlet
13200 mm
2
44000 mm
2