Loading ...
Loading ...
3
INSTALLATION REQUIREMENTS
Electrical Requirements—All Models
The electrical ratings for your dehumidier are listed on the model
and serial number label. The model and serial number label is
located on the right-hand side of the dehumidier cabinet.
Electrical Requirements
115 V (103.5 min.-126.5 max.)
0-12 A
15 A time-delay fuse or circuit-breaker
If ther
e is a “Single Circuit Only” label on the unit, use on a
dedicated single-outlet circuit only. If a dedicated single-outlet
circuit is not available, then it is the customer’s responsibility
to have a single-outlet circuit installed by a qualied
electrician.
If there is no “Single Circuit Only” label on the
unit, the unit may be used on any branch circuit
of correct voltage and adequate current
protection rating.
Recommended Grounding Method
This dehumidier must be grounded. This dehumidier is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer’s responsibility to have
a properly grounded 3 prong outlet installed by a qualied
electrical installer. It is also the customer’s responsibility:
To contact a qualified electrical installer.
T
o assure that the electrical installation is adequate and
in conformance with National Electrical Code, ANSI/NFPA
70 - latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Installation Instructions
WARNING
Excessive Weight Hazard
Use two or more people to move and install
dehumidifier.
Failure to do so can result in back or other injury.
Remove Packaging Materials:
Handle the dehumidier gently while unpacking the unit.
Remove the carton top and lift the dehumidier from the base
pad.
Remove tape and glue residue from surfaces before turning
on the dehumidier. Rub a small amount of liquid dish soap
over the adhesive with your ngers. Wipe with a damp cloth
and dry.
Do not use sharp instruments, rubbing alcohol, ammable
uids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your dehumidier.
Dispose of/recycle packaging materials in an appropriate way.
Loading ...
Loading ...
Loading ...