About the controls on the air conditioner—models with touch pads.
Auxiliary Controls – Temperature Limiting
To reach the auxiliary controls remove the front
grille. Access them through the small rectangular
opening above the control panel.
Temperature limiting can reduce energy
costs by limiting the lowest temperature that
can be set for cooling. Temperature limiting is
controlled by switches 1–3 of auxiliary controls.
Temperature limiting during COOL mode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 1, 2, 3 60° 85°
1 2, 3 64° 85°
1, 2 3 66° 85°
2 1, 3 68° 85°
2,3 1 70° 85°
1, 2, 3 NONE 72° 85°
1, 3 2 74° 85°
3 1, 2 76° 85°
1 32 4
UP
DOWN
TL1 (C) (Temp. Limit 1 – Cool)
TL2 (C) (Temp. Limit 2 – Cool)
TL3 (C) (Temp. Limit 3 – Cool)
No function (reserved
for future use)