34
Fault Cause troubleshooting
Water is dripping from the
brewing unit.
T DISC is damaged, leaking
or not correctly pierced.
Use a new TDISC.
Only use T DISCs once.
1. Wait until the brewing process has
come to an end and the appliance
has cooled down.
2. Remove the T DISC.
3. Clean the brewing unit.
→"Cleaning the appliance",
Page31
The piercing unit is not inser-
ted correctly.
Press the piercing unit into the
holder using both thumbs until it
clicks audibly into place.
There is water under the cup
stand.
Condensation has formed
due to technical reasons.
Remove excess water with a soft
cloth.
Information on display panel
Fault Cause troubleshooting
No LED is lit. Appliance is in idle mode.
Press .
All LEDs flashing. Voltage in the house system
is incorrect.
1. Pull out the mains plug and re-insert
it.
2. If the problem persists for a longer
period, have the voltage of your
property checked by an electrician.
LED lights up.
Water tank has not been suf-
ficiently filled.
1. Fill the water tank with fresh, cold
water up to the mark ⁠.
2. Insert the water tank.
LED lights up even
though there is enough wa-
ter in the water tank.
Float is stuck in the water
tank.
1. Descale the appliance.
→"Descale the appliance",
Page31
2. Reach into the water tank and
move the float up and down.
Water tank is wrongly inser-
ted.
1. Insert the water tank correctly.
2. Push the water tank into the appli-
ance until it clicks into place.
LED lights up.
Build-up of limescale in the
appliance.
Descale the appliance.
→"Descale the appliance",
Page31
Loading ...
Loading ...
Loading ...