Installation
43
c
Air vent positioned at top for recirculation
de
Mounting area (only d is required for recirculation hoods). Wall and ceiling
area for exhaust duct opening and for wall socket installation. Only the wall
socket installation is required for recirculation hoods.
Vent collar 6“ (150mm), with adapter 5” (125mm).
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the “IMPORTANT SAFETY
INSTRUCTIONS” section.
Minimum distance S
Cooking appliance Miele
appliance
Non-Miele
appliance
Electric Cooktops 24" (610 mm)
Electric Barbeques and Fryers 26" (660 mm)
Multiburner Gas Cooktops
43,000 BTU/hr (12.6kW),
no burner > 15,000 BTU/hr (4.5 kW).
26" (660 mm) 30" (760 mm)
Multiburner Gas Cooktops
73,800 BTU/hr (21.6kW),
no burner > 16,500 BTU/hr (4.8 kW)
30" (760 mm)
Multiburner Gas Cooktops
> 73,800 BTU/hr (21.6kW),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Not possible
Single Burner Gas Cooktops
20,500 BTU/hr (6 kW)
26" (660 mm) 30" (760 mm)
Single Burner Gas Cooktops
> 20,500 BTU/hr (6 kW)
27,600 BTU/hr (8.1 kW)
30" (760 mm)
Single Burner Gas Cooktops
> 27,600 BTU/hr (8.1 kW)
Not possible