4) Disconnect the suction tube. Allow the water tank to drain.
5) Spread out the tabs to unlock the water tank, then slide it out. See Fig. 38.
6) Lift off the ice chute from the front frame pipe and then from the rear frame pipe. See
Fig. 39.
Ice Chute
Front Frame Pipe
Ta b Ta b
Fig. 38 Fig. 39
Rear Frame Pipe
Water Tank
7) Disconnect the discharge tube from the spray assembly, then slide out the spray
assembly. See Fig. 40.
8) Remove the two caps. See Fig. 41.
Reducing Pipe
Rail
Rail
Fig. 42 Fig. 43
Discharge Tube
Spray Assembly
Fig. 40 Fig. 41
Right BracketLeft Bracket
Caps
Discharge Tube
Caps
9) Soak all of the removed parts and the scoop in the sanitizing solution for 10 minutes. If
the spray assembly nozzles are clogged, clean them with a wire or a suitable brush.
10) Rinse the parts thoroughly with clean water.
11) Reît the 2 caps in their correct positions. Make sure the reducing pipe is in place in the
center. See Fig. 42.
12) Slide in the spray assembly along the rails on the left and right brackets. See Fig. 43.
Connect the discharge tube securely to the spray assembly; a loose îtting may cause a
water leak.