To Disinfect:
Place Mist Outlet back into Water Tank.
Fill Base and Water Tank with a mixture of water and chlorine
bleach - mixed at a ratio of one (1) teaspoon of chlorine bleach
per 1 gallon of water (D). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
fully disinfect.
Rinse with water until bleach smell is gone. Dry with clean cloth or
paper towel.
Reinstall all components. Components must be securely in place
for unit to function properly.
1 tsp.
Chlorine Bleach
+
1 gal.
Water
Mineral Cartridge Replacement
The Mineral Cartridge removes minerals from the water thereby
softening the water and and reducing harmful mineral buildup on
the Transducer.
When to Replace: Many factors affect the frequency in which the
Cartridge will need to be replaced - including amount of use, water
hardness, and outside environmental factors. For heavy use, using
the unit continuously, we recommend replacing the Cartridge
approximately once a month. For lighter use, using the unit
intermittently, we recommend replacing the Cartridge every two
months.
The Cartridge will need to be replaced earlier if white powder residue
accumulates around the device. If the water used in the humidifier has
been treated by a decalcification system, the salt from the treatment can
show up as white dust also.
How to Replace:
Remove Water Tank (See FILLING WATER TANK for instructions)
Unscrew Cap.
Unscrew Mineral Cartridge from Cap (A). Discard Cartridge.
Install new Cartridge onto Cap.
If continuing use of Humidifier, fill Water Tank and reinstall Cap.
Replace Tank back into unit. Your Humidifier is now ready for use.
Note: the unit may take several minutes to create mist with the initial
use of a new Mineral Cartridge.
If storing unit, empty Water Tank and reinstall Cap. Replace Tank
back into unit. See STORAGE for instructions.