Replace all parts into position in the BBQ
Refit the burners and secure with the locking clips that hold
each burner in position. Replace the cooking plate.
NOTE: Check the operation of each burner
Adjustment of Low Flame Control Screw
Adjustment must be carried out for each of the burners.
Low flame adjustment screw is located in each valve,
under the knob. To set the low flame adjustment for NG,
the low flame adjustment screw is to be turned a full turn
anticlockwise. Use a 4mm wide, flat blade screwdriver.
Gas Leak Test Procedure
Use the following procedure to check for gas leaks. Never
use a naked flame to check for gas leaks.
1. In a small container, mix up a solution of water and
detergent or soap. Mix the solution well.
2. For LPG make sure that the gas supply valve on the gas
cylinder is turned on. For NG make sure that the gas
line is correctly fitted to the appliance.
3. Make sure that the gas control valves on the appliance
are all turned off.
4. Using a brush or spray bottle apply the solution to the
gas line and each join in the gas line.
5. Bubbling of the solution will indicate that there is a
leak present.
6. Re-tighten or re-seal any joints that are leaking.
7. If a leak persists then contact your distributor or the
manufacturer for assistance.
Use the following procedure to test the pressure.
8. Remove the right hand side burner.
9. Place a hose and pressure gauge over the right hand
side injector.
10. Turn the other burner on.
11. Turn the RH valve with measuring device on as well, and
take reading.
12. With at least one burner operating, the pressure reading
for Natural Gas should be 1.00KPa (10 mbar).
WARNING
WARNING
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odour continues, immediately call your gas supplier or
your fire department.
WARNING
WARNING
1. Do not store or use gasoline or other flammable vapours
or liquids in the vicinity of this or any other appliance.
2. An LPG cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
Replace the Data Label
Peel the gas type label from backing and cover existing data
label to indicate Natural Gas.
Technical Data Clubman BBQ
Bugg BBQ Main Burner
Natural Gas Jet size 1.50mm
LPG Jet size 0.9mm
Gas consumption 10Mj/9500BTU
Inlet pressure NG: 1KPa
LPG: 2.75 KPa
NATURAL GAS CONVERSION INSTRUCTIONS
P/N 020686
© 2017 Electrolux Home Products Pty Ltd. ABN 51 004 762 341
BMAN_BUGG_GASCONV_Oct17
For more information on all BeefEater products, or for
dimension and installation information, call into your retailer,
phone or email our customer care team or visit our website:
AUSTRALIA
phone: 1300 307 939
fax: 1800 356 669
email: customercare@electrolux.com.au
web: beefeaterbbq.com
NEW ZEALAND
phone: 0800 436 245
fax: 0800 225 088
email: customercare@electrolux.co.nz
web: beefeaterbbq.com