ELECTRICAL CONNECTIONS
1. Install three wires: black, white and green (#16 AWG) in ½” conduit from the service panel to the hood junction
box. Power supply must be rated for 120v, 60 Hz, 15 amps (minimum).
2. Remove junction box and run power line through single hole and route to junction box mounted on back.
3. Connect black wire to power supplied black wire, white wire to power supplied white wire and green wire to
ground supply green wire.
4. Place all wiring connectors inside junction box and re-install on back panel.
22