Features and Controls
120 Volt AC, 20 Amp, GFCI Duplex Receptacles — Used
to supply 120 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — Used to
supply 120/ 240 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
Circuit Breakers — The 120 Volt AC, 20A GFCI duplex
receptacles are provided with “push to reset” 20 Amp
circuit breakers to protect the generator against electrical
overload.
CO Guard™ Carbon Monoxide (CO) Shutdown Indicator
Light — Indicates the engine shutdown due to carbon
monoxide accumulation around the generator or a CO
Guard system fault occurred.
Low Oil Shutdown — This unit is equipped with a low oil
protection device. Oil must be at proper level for engine
to run. If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with dipstick.
Main Breaker — Protects generator against electrical
overload. If breaker trips, it cuts power to all receptacles.
On/Off Switch — Set this switch to ON (I) before starting
engine. Set switch to OFF (0) to shut off engine.
Start Switch — Push and hold in “Start” position for a
maximum of 5 seconds during each start attempt, until
engine starts.
Main Breaker
120/240 Volt AC, 30
Amp Locking Receptacle
120 Volt AC, 20 Amp
GFCI Duplex Receptacles
Low Oil
Shutdown
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and product warnings.
On/Off Switch
Start Switch
Circuit Breakers
CO Guard™
Carbon Monoxide
(CO) Shutdown
Indicator Light