Neff D57ML66N1/01 User Manual
User Manual Neff D57ML66N1/01 N 70 Canopy hood
Documents for Neff D57ML66N1/01
The following documents are available:
User Manual
User Manual - (English)
Read Online
|
Download pdf
Other Documents
Instruction manual - (English)
Download
Photos
Photos:
View Photos
User Manual
For D57ML66N1/01.
Page 1/8
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Contents
Table of Contents
Search
Previous
Next
Bookmarks
*9001018801*
Ú
,QVWDOODWLRQLQVWUXFWLRQV
[
[
ʦ
$
%
Loading ...
Loading ...
Loading ...
1
2
3
4
5
6
>
Summary of Contents for Neff D57ML66N1/01:
: Important safety information
5
Danger of death!
5
Risk of death!
5
Danger of suffocation!
5
Risk of electric shock!
5
Risk of electric shock!
5
Risk of fire!
5
Risk of fire!
5
Risk of injury!
5
Risk of injury!
5
Risk of injury!
5
Risk of injury!
5
General information
5
Exhaust duct
5
Note
5
Electrical connection
6
: Risk of electric shock!
6
Installation preparation
6
Checking the fitted unit
6
Appliance dimensions and safety clearances
6
Preparing the units
6
1. Make the cut-out in the fitted unit. (Fig. 1a)
6
2. Make the cut-out for the exhaust air pipe.
6
Note
6
Preparing the appliance
6
1. Open the filter cover. (Fig.2a)
6
Note
6
2. Undo the hinge lock and remove the filter cover. (Fig.2b)
6
3. Remove the metal grease filter; see the instruction manual.
6
4. Disconnect the cabling for the control panel and the lighting. (Fig.2c)
6
5. Undo the screws in the frame and remove the frame. (Fig.2d)
6
6. Optional for air recirculation:
6
Installing the appliance
6
1. Place the appliance into the opening in the fitted unit and screw it to the fitted unit. (Fig. 3a)
6
2. Tighten the fastening screws. (Fig. 3b)
6
3. Disconnect the cabling for the control panel and the lighting.
6
4. Put the frame in place and screw it to the appliance from below. (Fig. 3c)
6
5. Secure the frame and the appliance with screws. (Fig. 3d)
6
Note
6
6. Insert the metal grease filter.
6
7. Attach and close the filter cover.
6
Connecting the appliance
6
Notes
6
Establishing the connection for the exhaust air (Fig. 4a)
6
Note
6
1. Attach the exhaust air pipe directly to the air pipe connector.
6
2. Connect it to the exhaust air opening.
6
3. Seal the joints appropriately.
6
Establishing the connection for the circulated air (Fig.4b )
6
Notes
6
1. Attach the exhaust air pipe directly to the air pipe connector.
6
2. Establish the connection to the opening on the fitted unit.
6
3. Screw the air guide grille to the fitted unit.
6
4. Seal the joints appropriately.
6
Connecting the air recirculation module (Fig.4c )
6
Note
6
1. Refer to the printed supplement for the air recirculation module.
6
2. Attach the exhaust air pipe directly to the air pipe connector.
6
3. Connect the pipe to the opening on the air recirculation module.
6
4. Use suitable means to seal the joints.
6
5. Insert the activated charcoal filter.
6
Removing the appliance
6
1. Disconnect the appliance from the power supply.
6
2. Disconnect the exhaust air lines.
6
3. Open the filter cover.
6
4. Remove the grease filter.
6
5. Disconnect the cabling for the control panel and the lighting.
6
6. Remove the frame.
6
7. Undo the fastening to the fitted unit.
6
8. Remove the appliance.
6
File type: PDF
File name: 1855409_d57ml67n1b-02.pdf
File size: 399.15 KB
File Language: English
Pages: 8
Author: Neff
Published: 2021-01-17
Updated: 2023-06-12
Download File
Specifications
Brand:
Neff
Model: D57ML66N1/01
Category:
Hoods
See other models:
D55ML66N0/01
H11WE60S0G/03
KI2223D40/04
T4553X2/09
E3422S0/03
Photos
Download User Manual
Related Products
Neff D57ML66N0/01
Neff D57ML66N1/02
Neff D55ML66N1/01
Neff D57ML66N0/02
Neff D57ML66N0/03
Neff D57MH56N0/01
Neff D57ML67N0/01
Neff D55ML66N0/01
Neff D55ML66N1/02
Neff D57MH56N0B
Neff D57ML67N0B
Neff D57ML67N1B
Neff D58ML66N1
Neff D57ML67N1A
Neff D58ML66N1A
Table of Contents
×
: Important safety information
5
Danger of death!
5
Risk of death!
5
Danger of suffocation!
5
Risk of electric shock!
5
Risk of electric shock!
5
Risk of fire!
5
Risk of fire!
5
Risk of injury!
5
Risk of injury!
5
Risk of injury!
5
Risk of injury!
5
General information
5
Exhaust duct
5
Note
5
Electrical connection
6
: Risk of electric shock!
6
Installation preparation
6
Checking the fitted unit
6
Appliance dimensions and safety clearances
6
Preparing the units
6
1. Make the cut-out in the fitted unit. (Fig. 1a)
6
2. Make the cut-out for the exhaust air pipe.
6
Note
6
Preparing the appliance
6
1. Open the filter cover. (Fig.2a)
6
Note
6
2. Undo the hinge lock and remove the filter cover. (Fig.2b)
6
3. Remove the metal grease filter; see the instruction manual.
6
4. Disconnect the cabling for the control panel and the lighting. (Fig.2c)
6
5. Undo the screws in the frame and remove the frame. (Fig.2d)
6
6. Optional for air recirculation:
6
Installing the appliance
6
1. Place the appliance into the opening in the fitted unit and screw it to the fitted unit. (Fig. 3a)
6
2. Tighten the fastening screws. (Fig. 3b)
6
3. Disconnect the cabling for the control panel and the lighting.
6
4. Put the frame in place and screw it to the appliance from below. (Fig. 3c)
6
5. Secure the frame and the appliance with screws. (Fig. 3d)
6
Note
6
6. Insert the metal grease filter.
6
7. Attach and close the filter cover.
6
Connecting the appliance
6
Notes
6
Establishing the connection for the exhaust air (Fig. 4a)
6
Note
6
1. Attach the exhaust air pipe directly to the air pipe connector.
6
2. Connect it to the exhaust air opening.
6
3. Seal the joints appropriately.
6
Establishing the connection for the circulated air (Fig.4b )
6
Notes
6
1. Attach the exhaust air pipe directly to the air pipe connector.
6
2. Establish the connection to the opening on the fitted unit.
6
3. Screw the air guide grille to the fitted unit.
6
4. Seal the joints appropriately.
6
Connecting the air recirculation module (Fig.4c )
6
Note
6
1. Refer to the printed supplement for the air recirculation module.
6
2. Attach the exhaust air pipe directly to the air pipe connector.
6
3. Connect the pipe to the opening on the air recirculation module.
6
4. Use suitable means to seal the joints.
6
5. Insert the activated charcoal filter.
6
Removing the appliance
6
1. Disconnect the appliance from the power supply.
6
2. Disconnect the exhaust air lines.
6
3. Open the filter cover.
6
4. Remove the grease filter.
6
5. Disconnect the cabling for the control panel and the lighting.
6
6. Remove the frame.
6
7. Undo the fastening to the fitted unit.
6
8. Remove the appliance.
6