o The correct adjustment is obtained when the flame has a length
of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning from
maximum flow to minimum flow. If it does then remove the
control knob and make further adjustments to the gas flow,
testing it again once the adjustment has been made.
o IMPORTANT: On completion carry out a gas tightness test.
Gas adjustment (Conversion to LPG for the oven and grill)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Free the burners from their
fixing screws.
35
).
o Unscrew the injectors and replace
them with the stipulated injector
for the new gas supply (see table
on page 33 - 34
IMPORTANT: You must change the oven and grill injectors.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section below.