Chart Definitions
Freeze timer = Freeze time in seconds.
Harvest timer = Harvest time in seconds.
Freeze Counter = Continuous freeze cycles (starts over after bin full, power interruption, or ice
melt state)
Flush level set point = Flush level setting 0-5.
Flush used = 1-5. Flush level used in autoflush (0) mode.
Water quality = An indication of water quality where 0-24 Extremely Mineral Laden; 25-30
Somewhat Mineral Laden; 31-65 Normal; 66-120 Very Clean; >120 Extremely Clean
Error code - Diagnostic Error Code. Codes listed in software and on next page.
Op mode = the current mode of the controller. Modes listed in software and on next page.
Sump temperature = Reservoir water temperature in degrees F
Discharge temperature = Discharge temperature in degrees F
Supply voltage = approximation of AC voltage to the control board from the transformer.
Bin stat = Bin thermostat, when used. 0 open, 1 closed
RLO = SmartLock option. 0 not locked, 1 locked
Ready to Harvest = Ice thickness sensor. 0 no ice, 1 ice
Sump Full = Water level sensor. 0 no water, 1 water
Sump Empty = Water level sensor. 0 no water, 1 water
Remote = 0 not remote, 1 remote
Curtain SW1 = 0 closed, 1 open
Curtain SW2 = 0 closed, 1 open
Water Solenoid=0off,1on
Water Pump=0off,1on
Hot Gas = 0 off, 1 on
Condenser Fan/Aux=0off,1on
Compressor=0off,1on
Purge Valve=0off,1on
Power up time= Time power connected to machine.
Compressor run = Time compressor has been operating
Power interrupts = Number of electrical power interruptions to the machine
Bin setpoint = Set point of the ice level control
Bin level (inches) = Ice level measured by the ice level control
HGV counter = Number of times the hot gas valve has cycled. Equals harvest cycles.
Auto flush level min = minimum level flush can be set to when set to automatic
CB0522 through CB1030