Connecting to external ducting
8) Connect the coupling to the top of the cooker hood, and then
connect a 125 mm ducting hose to the coupling (please note that the
ducting hose is not supplied with the appliance).
o The other end of the ducting hose should be connected to a
discharge outlet that is suitable for cooking vapours. It should
have a cross section of at least 150 cm².
o The maximum distance between the coupling and your discharge
outlet should be 3 metres, with one 90 degree bend. For each
additional 90 degree bend, the maximum distance is reduced by
a further metre.
Fitting the chimney
9) Take the two chimney sections
(C) and (D).
o Rest the bottom of chimney
section (C) on the top of the
hood. You should take care to
position the tabs on the
chimney section into the rear
of the hood.
o Mark the side measurement of
both sides of the chimney
section (C) on the wall with a
pencil.