12 | P a g e
OPERATION INSTRUCTIONS
BEFORE USING YOUR PORTABLE AIR CONDITIONER
Remove the exterior and interior packaging.
Before connecting the unit to the power source, let it stand upright for approximately 4
hours. This will reduce the possibility of a malfunction in the cooling system from handling
during transportation.
SWITCHING ON/OFF THE AIR CONDITIONER
The unit can be switched ON or OFF by pressing the Power button on the control panel or
the Power button on the remote control.
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function
mode, press the Mode Control button until the GREEN indicator comes on. When the cooling
mode is set, the compressor will start in approximately 3 minutes.
NOTE: In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust
hose must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F to 89°F. To set the
temperature, press the + or - buttons. This air conditioner has a 5°F temperature cushion which
if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode.
This saves energy and prolongs the life of the compressor of the air conditioner. Once the set
temperature is achieved, the fan runs continuously.
To set the fan speed, press the Fan Speed button. In cooling mode, the difference in noise
level between the 3 fan speeds is not very noticeable when the compressor is on. Try
setting the unit to Fan only mode, you should be able to hear the difference between high and
low fan speed settings.
DEHUMIDIFYING MODE
In this mode, the air conditioner dehumidifies the room, the compressor will activate
intermittently depending on the ambient temperature and the fan speed is set to Low. To
activate dehumidifying mode, press the Mode Control button until the PURPLE indicator
illuminates. When switching between functions, there will be an approximate 3 minute
transition time.
In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is
vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust
hose from the window kit and allow the warm air from the rear to be re-circulated into the
room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room
temperature is lower than 77°F, the fan speed is set at Low.
Note:
When using dehumidifying mode, venting the exhaust hose to the outside is not required. If
vented, the warm air is exhausted to the outside and cooling within the room may occur.
Additionally, if the exhaust hose is not vented, the unit may require more frequent draining.
The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY
MODE
In this mode, only the fan of the air conditioner runs and circulates the air within the room. To
activate fan only mode, press the Mode Control button until the YELLOW indicator
illuminates. In this mode, the temperature cannot be set. Subsequently, set the desired fan
speed by pressing the Fan Speed button.
Note: When using fan only mode, venting the exhaust hose to the outside is not required.