Electrical Requirements
Installation must comply with all applicable electrical
codes.
Locate the electrical supply flush with the wall or floor
and within the shaded area shown in the illustration on
page 7. A separate circuit servicing only this appliance is
required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 30 or 50
amps (refer to the chart below), and must include 3 or 4
conductors. A 4-conductor cord is required for installa-
tions where grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp dedicated circuit
Total Amps 21
Max Connected Load 5.2 kW
ELECTRICAL REQUIREMENTS—DOUBLE OVEN
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 50 amp dedicated circuit
Total Amps 42.5
Max Connected Load 10.2 kW
Installation Requirements
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 10"
(254) riser is required for a 36" dual
fuel range with charbroiler or griddle and all 48" and 60"
models. Follow all minimum clearances to combustible
surfaces shown in the illustration on page 7.
Specifications
RATING PLATE
Rating plate location