Elica EHL640WH 39 Inch Ceiling Mounted Range Hood with 600 C

User Manual - Page 5

For EHL640WH.

PDF File Manual, 40 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
5
Use
The hood is designed to be used for exhausting version.
In this case the fumes are conveyed outside of the building by
means of a special pipe connected with the connection ring
located on top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the
connection ring.
CAUTION!
If the hood is supplied with active charcoal filter, then it must be
removed.
Connect the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller
dimensions will cause a diminution of the suction performance and
a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensable length.
! Use a duct with as few elbows as possible (maximum elbow
angle: 9).
! Avoid drastic changes in the duct cross-section.
Installation
Specialised personnel must carry out both the electrical and
the mechanical installation.
Do not cut a joist or stud unless absolutely necessary. If a joist or
stud must be cut, then a supporting frame must be constructed.
Fittings material is provided to secure the hood to most types of
walls/ceilings.
However, a qualified technician must verify suitability of the
materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance within
the ceiling or wall for exhaust vent.
Hood installation height above cooktop is the users preference.
The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
CAUTION: FOR GAS RANGES INSTALLATION: MOUNT THIS
HOOD SO THAT THE BOTTOM EDGE IS AT 39" (99 CM)
ABOVE THE COOKING SURFACE.
FOR ELECTRIC RANGES INSTALLATION: MOUNT THIS
HOOD SO THAT THE BOTTOM EDGE IS NOT LESS THAN 30"
(76,2 CM) ABOVE THE COOKING SURFACE.
HOUSEHOLD USE. PLEASE, READ INSTALLATION MANUAL
FOR SPECIFIC APPLICATION.
Check your ceiling height and the hood height maximum
before you select your hood.
Consult last pages of this manual for installation instruction
and electrical connection steps.
Operation
This product is designed to work with an Elica remote control,
either supplied with the product or purchased separately as an
optional.
To control the hood via remote control, the affiliation procedure
must be carried out.
CAUTION!
To begin, the hood must be disconnected and then reconnected to
the power supply and the affiliation procedure must be carried out
within the first minute of connection to the power.
Read the instructions supplied with the remote control, which
provide detailed instructions on affiliation and correct use.
Note: the Speed 4 (and the Speed 5, where applicable) if
selected, will activate for a limited period of time after which Speed
2 is automatically enabled.
Remote control connection (if applicable)
Once the remote control has been connected, this will be
displayed on the hood:
both LEDs flash.
Note: Using the remote control, delayed shut-down can be
programmed based on the aspiration speed (power) enabled at
that moment:
Speed 1 (low aspiration): 20 minutes
Speed 2 (medium aspiration): 15 minutes
Speed 3 (high aspiration): 10 minutes
Filter Saturation indicator lights
At regular intervals, the LEDs on the hood indicate the need to
carry out filter maintenance.
Note: The filter saturation signal is visible for a few seconds when
the hood is switched on; within this time, the saturation
indicator lights must be reset.
Flashing Green LED: carry out maintenance on the grease
filter.
Red flashing LED: carry out maintenance on the charcoal
filter (only for hoods operating in "Filtration Version").
Note: Run the "RESET FILTRES" command via the remote
control.
Activating/deactivating the filter saturation indicator light
Note: Run the procedure with the hood switched off. The
charcoal filter saturation indicator light is usually deactivated.
If no control is given within maximum 10 sec, the hood
Loading ...
Loading ...
Loading ...