Cybex VR1 13200 Abdominal/Back Extension Medical Owner’s Manual
Maintenance
Page 4-2
1. Check all nuts and bolts for looseness. Tighten as required.
2. Inspect all cables for wear or damage and proper tension. When inspecting cables, run
ngers on the cable, paying particular attention to bends in cable and attachment points.
WARNING: Replace all worn cables immediately. The following conditions may indicate a worn cable:
A tear or crack in the cable sheath that exposes the cable. See Figure 1.
Weekly Procedures
A kink in the cable. See Figure 2.
Figure 2
A curled sheath. See Figure 3.
Figure 3
“Necking”, a stretched cable sheath. See Figure 4.
Figure 1
Figure 4