31
Instructions for the installer
11.2 Room ventilation and combustion extraction
The room containing the appliance should have an air supply in accordance with the standards in force.
The room where the appliance is installed must have enough air flow as required for the regular
combustion of gas and by the necessar y air exchange of the same room. The air vents, protected by
grills, must be suitably dimensioned in compliance with the current regulations and positioned so that no
part of them is obstructed.
The appliance must be kept adequately ventilated in order to eliminate the heat and humidity produced
by cooking: in particular, after prolonged use, you are recommended to open a window or to increase the
speed of any fans.
Combustion products can be extracted by means of hoods connected to a natural draught chimney
whose efficiency is assured or via forced extraction. An efficient extraction system requires precision
planning by a specialist qualified in this area and must comply with the positions and distances indicated
by the regulations. When the job is complete, the installer must issue a certificate of conformity.
Extraction using a hood.
Extraction without a hood.
Single natural draught chimney.
Single chimney with extractor
fan.
Directly outdoors with wall- or
window-mounted extractor fan.
Directly outdoors through wall.
Air
Combustion products
Extractor fan