28 Part Number 000015433_02 11/19
Step 11 Reassemble ice machine.
Step 12 Turn off the ice making water supply.
Step 13 Refer to chart and premix water and sanitizer.
Amount of Water Amount of Sanitizer
1 Gallons (4 L) Water 1/2 ounce (15 ml)
Step 14 Fill the evaporator and reservoir with sanitizer/
water solution.
Step 15 Move the toggle switch to the ON position. The
ice machine will make ice with the sanitizer/water solution
and deposit the ice in the bin. Add the remaining sanitizer/
water solution when the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop below
the minimum water level. The ice machine will discontinue
the cleaning cycle if the water float switch opens.
Step 16 After all of the sanitizer/water solution has
been added to the reservoir, turn on the ice making water
supply.
Step 17 Continue the freeze cycle for 30 minutes and
then discard all ice produced.