STEP 6 - Option 1: Installing on a wood stud wall
Note: Drywall covering the wall must not exceed 5/8" (16 mm).
1 Locate the stud. Verify the center of the stud with an edge-to-edge stud finder.
2 Align the center of the wall plate template (11) at the height you determined in
the previous step and make sure that it is level. Tape the wall plate template to
the wall, then use a pencil to mark the lag bolt hole locations (2) on the stud
centers. Remove the wall plate template.
3 Drill pilot holes to a depth of 2 3/4 in. (69 mm) using a 7/32 in. (5.5 mm) diameter
drill bit.
Note: Minimum wood stud size: Common 2 x 4 in. (51 x 102 mm). Nominal 1.5 x 3.5 in. (38 x 89 mm)
4 Align the wall plate (12) with the pilot holes, insert the lag bolts (13) through the
holes in the wall plate assembly, then tighten the lag bolts only until they are
firm against the wall plate assembly.
CAUTION: Avoid potential injuries or property damage!
DO NOT over-tighten the lag bolts (13).
Y
UP
Y
U
U
P
U
2 3/4 in.
(69 mm)
7/32 in.
(5.5 mm)