Loading ...
Loading ...
Loading ...
4
Location Requirements
You will need
A location that allows for proper exhaust installation. See
“Venting Requirements.”
A separate 30-amp circuit.
A grounded electrical outlet located within 2 ft (610 mm) of
either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the dryer weight (dryer and load)
of 115 lbs (52 kg). The combined weight of a companion
applia
nce should also be considered.
A level floor with a maximum slope of 1" (25 mm) under
entire dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC).
At lower temperatures, the dryer might not shu
t off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some cod
es limit, or do not permit,
installation of the dryer in garages, closets, mobile
homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to
open fully.
23
7
8
(606 mm)
"
20
3
4
(527 mm)
"
31"
(787 mm)
*
Dryer Dimensions
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbows. See “Venting
Requirements.”
Minimum spacing for recessed area and closet installation
The following dimensions shown are for the minimum spacing
allowed when the dryer is to be operated with, or without, the
Stack Stand Kit. To purchase a Stack Stand Kit, see “Assistance
or Service.”
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
A. Side view - closet or confined area
B. Recessed area
A B
3"*
(76 mm)
14"*
(356 mm)
18"* (457 mm)
1"
(25 mm)
1"
(25 mm)
Recessed or closet installation - Stacked
DRYER
WASHER
(76 mm)
3"*
(305 mm)
12"*
(305 mm)
12"*
1"
(25 mm)
1"
(25 mm)
A B
C
1"*
(25 mm)
3"*
(76 mm
)
48 in. *
2
(309.7 cm )
2
24 in. *
2
(154.8 cm )
2
3"*
(76 mm
)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Mobile Home - Additional Location Requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 245, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Loading ...
Loading ...
Loading ...