Installation requirements
Installation requirements
Gas and Electrical Service
The shaded area shown below denotes the location of the gas inlet and the electrical
junction box/receptacle. This is the recommended location. For replacement purposes,
the location of the existing utilities may be utilized provided they do not interfere with
the sides or rear of the range. Check local building codes for permissible gas valve
locations.
An external manual shut-off valve must be installed between the gas inlet and the
range for the purpose of turning on or shutting off gas to the appliance. The installation
must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box, when the range is in place.
The gas supply piping and shut-off valve, and the electrical junction box/receptacle
must be located so they do not interfere with the range when it is installed.
The junction box and gas shut off valve must be located so that the range can be pulled
out for service while the appliance remains connected.
G
E
D
F
Recommended
position for Gas stub
Recommended
position for
Electrical outlet
Model D E F G
DOP36M94DL*
8 7/8"
(22.5 cm)
6 5/8"
(16.8 cm)
11 3/16"
(28.4 cm)
24 1/4"
(61.6 cm)
DOP48M96DL*
5 1/2"
(13.9 cm)
6 5/8"
(16.8 cm)
8 1/8"
(20.6 cm)
26 5/8"
(67.6 cm)
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 30 2017-05-12  7:36:47