Cafe CGU486P3TD1 48" Matte Black Commercial-Style Natural Gas Rangetop With 6 Burners And Griddle

User Manual - Page 11

For CGU486P3TD1.

PDF File Manual, 56 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
31-2000816 Rev. 0 11
Installation
5
GAS SUPPLY
WARNING
Fire Hazard: Do not use a flame to
check for gas leaks.
WARNING
([SORVLRQ+D]DUG'RQRWH[FHHG
IWOEVRIWRUTXHZKHQPDNLQJJDVOLQHFRQQHFWLRQV
Overtightening may damage the pressure regulator
UHVXOWLQJLQILUHRUH[SORVLRQKD]DUG
Gas Pressure Regulator
<RXPXVWXVHWKHJDVSUHVVXUHUHJXODWRUVXSSOLHG
ZLWKWKLVUDQJHWRS)RUSURSHURSHUDWLRQVWKHLQOHW
SUHVVXUHWRWKHUHJXODWRUVKRXOGEHDVIROORZV
Natural Gas:
Minimum pressure: 6” of Water Column
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
If you are not sure about the inlet pressure contact
local gas supplier.
Shut off the main gas supply valve before
disconnecting the old rangetop and leave it off
until the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
Because hard piping restricts movement of the
UDQJHWRSWKHXVHRID&6$,QWHUQDWLRQDOFHUWLILHG
IOH[LEOHPHWDODSSOLDQFHFRQQHFWRULVUHFRPPHQGHG
XQOHVVORFDOFRGHVUHTXLUHDKDUGSLSHGFRQQHFWLRQ
,IWKHKDUGSLSLQJPHWKRGLVXVHGFDUHIXOO\DOLJQ
WKHSLSHWKHUDQJHWRSFDQQRWEHPRYHGDIWHUWKH
connection is made.
7RSUHYHQWJDVOHDNVSXWSLSHWKUHDGVHDODQWRQRU
ZUDSSLSHWKUHDGWDSHZLWK7HIORQDURXQGDOOPDOH
H[WHUQDOSLSHWKUHDGV
A. Install provided pressure regulator directly to the
JDVLQOHWSLSHRIWKHUDQJHWRS5HIHUWRWKHDUURZ
RQWKHEDFNRIWKHUHJXODWRUIRUJDVIORZGLUHFWLRQ
(QVXUHWKHIURQWRIWKHUHJXODWRULVIDFLQJWRZDUGV
WKHFDELQHWIURQWHDVLO\DFFHVVLEOHWKURXJKWKH
cabinet doors.
% ,QVWDOODPDQXDOVKXWRIIYDOYHLQWKHJDVOLQHLQD
location easily accessible through the cabinet doors.
& :KHQDOOFRQQHFWLRQVKDYHEHHQPDGHHQVXUHDOO
gas controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.
*Teflon: Registered trademark of DuPont
5
GAS SUPPLY (cont.)
:KHQXVLQJSUHVVXUHVJUHDWHUWKDQSVLJWR
SUHVVXUHWHVWWKHJDVVXSSO\V\VWHPRIWKHUHVLGHQFH
GLVFRQQHFWWKHUDQJHWRSDQGLQGLYLGXDOVKXWRIIYDOYH
from the gas supply piping. When using pressures
RISVLJRUOHVVWRSUHVVXUHWHVWWKHJDVVXSSO\
V\VWHPVLPSO\LVRODWHWKHUDQJHWRSIURPWKHJDV
VXSSO\V\VWHPE\FORVLQJWKHLQGLYLGXDOVKXWRIIYDOYH
:KHQFKHFNLQJIRUSURSHURSHUDWLRQRIWKHUHJXODWRU
the inlet pressure must be at least 1” greater than the
operating (manifold) pressure as given on rating label
of product.
CONNECTOR HOOKUP
7<3,&$/,167$//$7,21:,7+12
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
A. ´137PDOHSLSH
thread
B. 5HJXODWRUSURYLGHGZLWK
unit:
2XWOHW´137
female pipe thread
,QOHW´137IHPDOH
pipe thread
C. Adapter
D. )OH[LEOHFRQQHFWRU
E. Adapter
F. 0DQXDOVKXWRIIYDOYH
G. *DVSLSH´RU´
A. ´137PDOHSLSHWKUHDG
B. EOERZ
C. Adapter
D. )OH[LEOHFRQQHFWRUDOORZV
SDVVDJHWKURXJKFDELQHWZDOO
E. Adapter
F. 5HJXODWRUSURYLGHGZLWKXQLW
2XWOHW´137IHPDOH
pipe thread
,QOHW´137IHPDOHSLSH
thread
G. Gas pipe
H. 0DQXDOVKXWRIIYDOYH
I. *DVSLSH´RU´
ALTERNATE INSTALLATION WITH
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
I
H
Loading ...
Loading ...
Loading ...